#1 Global Leader in Data Resilience

Release Information for NEC Storage M Series Plug-In for Veeam Backup & Replication

KB ID: 4274
Product: Veeam Backup & Replication | 11 | 12 | 12.1 | 12.2 | 12.3 | 12.3.1
Published: 2022-01-21
Last Modified: 2025-02-04
mailbox
Get weekly article updates
By subscribing, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.

Cheers for trusting us with the spot in your mailbox!

Now you’re less likely to miss what’s been brewing in our knowledge base with this weekly digest

error icon

Oops! Something went wrong.

Please, try again later.

This plug-in leverages the Veeam Universal Storage API, which enables storage OEMs to allow Veeam Backup & Replication integration to the arrays for backup and replication jobs.

Requirements

Before installing NEC Storage M Series Plug-In v1.0.9, ensure that you are running Veeam Backup & Replication 11.0.0.837 or later. To check the version, open the main menu of the Veeam Backup & Replication console and select Help > About.

NEC Storage M Series Plug-In v1.0.9 supports integration with the following storage systems:

  • M120, M320, M320F, M520, M720, M720F (Storage Control Software revision 1234 or later)

The following licenses are required on the NEC storage:

  • BaseProduct
  • AccessControl
  • ThinProvisioning
  • DynamicDataReplication
  • DynamicSnapVolume
  • Volume Clone

Follow detailed instructions on configuring the NEC Storage M Series Plug-in and the storage system in the NEC documentation [ ENG | JPN ].

Known Issues

The following is a list of known major issues for NEC Storage M Series Plug-In for Veeam Backup & Replication.

  • For iSCSI, the NEC plug-in requires the host OS platform for backup proxies to be explicitly specified using the "OS Type" setting in the VeeamProxyOSType.xml configuration file. By default, hosts are auto-created with the Windows ("WN") type; to use a Linux proxy, the "OS Type" setting needs to be set to "LX". The proxy type for existing hosts can be changed later using the "Platform" setting for the host (LD Set) in the storage settings.
  • Setups with IPv6 ports configured on the storage are not supported. Make sure the storage doesn't have IPv6 addresses configured.
  • Virtual FC is not supported for connections between proxy and NEC storage.
  • NEC storage plug-in will not work with FIPS policy enabled on the Veeam Backup & Replication server.
  • The backup of VMs on datastores built with multiple disks (LUNs) is not supported.
  • When there is a high load on the storage, the storage may fail to handle some plug-in requests. Please contact technical support to verify the reasons for the failures and get assistance with increasing the number of operation retries and retry timing.
  • Some operations may fail with the message "The solution map is not large enough" when storage resource limitations in terms of Logical Disk size are reached. This might result from a large number of snapshots and clones created on the storage. You may want to try running fewer jobs in parallel and create jobs with fewer VMs to avoid that.
  • To reduce the processing time of the rescan operation, the snapshot clones created during a rescan (one clone per snapshot) are not immediately removed during the unexport operation; instead, they are removed when the snapshot itself is deleted.
  • If parallel backup jobs attempt to delete different snapshots on the same volume, the operation may fail with the "iSM19108: The volume under deletion exists" message. If this happens frequently, stagger the execution timing of backup jobs.
  • Storage can only be added to Veeam Backup & Replication using storage management account credentials. The management account of the storage management software cannot be used.
  • Storage time zone and backup server time zone must match.
  • The NEC plug-In does not support backing up failover clusters using Veeam Agent for Microsoft Windows.
  • Using Veeam Agent for Microsoft Windows to create backups from storage snapshots requires Veeam Backup & Replication 11a or later.
  • When using Veeam Agent for Microsoft Windows, the maximum LUN size depends on the amount of RAM available on the storage (e.g., 48TB LUN for 64GB RAM).

Download Information

MD5: a02978fdab13c13bc924046566a71123
SHA1: 814a732c640900e9bd01f68e112641f9cce45bb6
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

Veeam Backup & Replication
Veeam Data Cloud for Microsoft 365
Veeam Data Cloud for Microsoft Entra ID
Veeam Data Cloud for Salesforce
Veeam Data Cloud for Microsoft Azure
Veeam Data Cloud Vault
Veeam Backup for Microsoft 365
Veeam Backup for Microsoft Entra ID
Veeam Backup for Salesforce
Veeam ONE
Veeam Service Provider Console
Veeam Agent for Microsoft Windows
Veeam Agent for Linux
Veeam Backup for Nutanix AHV
Veeam Backup for AWS
Veeam Backup for Microsoft Azure
Veeam Backup for Google Cloud
Veeam Backup for Oracle Linux Virtualization Manager and Red Hat Virtualization
Veeam Management Pack for Microsoft System Center
Veeam Recovery Orchestrator
Veeam Agent for Mac
Veeam Agent for IBM AIX
Veeam Agent for Oracle Solaris
Veeam Cloud Connect
Veeam Kasten for Kubernetes
By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please, try again later.