#1 Global Leader in Data Resilience

Veeam Availability Orchestrator v2 Patch 1 (build 1463)

KB ID: 2992
Product: Veeam Recovery Orchestrator
Version: 2.0.1.1403
Published: 2019-08-27
Last Modified: 2020-08-13
mailbox
Get weekly article updates
By subscribing, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.

Cheers for trusting us with the spot in your mailbox!

Now you’re less likely to miss what’s been brewing in our knowledge base with this weekly digest

error icon

Oops! Something went wrong.

Please, try again later.

Challenge

This patch fixes the following issue found in VAO 2.0. The presence of backup job objects created by Veeam plug-in backup jobs cause VAO Restore Plans to fail locating valid restore points required for the restore process.

The following example shows the issue found in the Readiness Check Report: both the Infrastructure Checks and Recovery Step Checks sections of the report display the same error for the Restore Point check. The issue can also be found in any VAO report.
User-added image
User-added image

Solution

To install the patch, perform the following steps: 

1. Prepare your VAO environment for the installation process.
 
Make sure all VAO processes are stopped or halted on the VAO server. To do that, in the VAO UI, check that:

• No orchestration plans are in the IN USE mode (that is, all plans are neither started nor being edited).
• No readiness checks and lab tests are running.
• No reports are being generated.

2. Install the patch on the VAO server.
 
On the VAO server, launch the patch installer (VAO.Server.x64_2.0.1.1463.msp), complete the installation wizard and start installation.

As soon as the installation process completes, the patch will be installed on both the VAO server and the embedded VAO agent. The following files will be updated:

• <VAOSetupFolder>\Server\Veeam.AA.Agent.exe  
• <VAOSetupFolder>\Server\Veeam.AA.AgentCommunication.dll
• <VAOSetupFolder>\Server\Veeam.AA.Server.exe  
• <VAOSetupFolder>\Server\AgentPackage\Veeam.AA.DeployService.exe
• <VAOSetupFolder>\Server\AgentPackage\VAO.Agent.x64.msi

3. Install the patch on all VAO agents. 
To install the patch on VAO agents running on Veeam Backup & Replication servers and Veeam Backup Enterprise Manager servers connected to VAO, do the following :

a. Log in to the VAO UI as a VAO Administrator.
b. Navigate to Administration > VAO Agents.
c. Select the VAO agent that must be repaired (the Agent Version column will display a version number lower than 2.0.1.1463 for this agent).
d. Click Repair and complete the Repair VAO Agent wizard.
e. Repeat steps c-d for each VAO agent whose version is lower than 2.0.1.1463.

As soon as the repair process completes, your agents will be updated to version 2.0.1.1463.

4. Run readiness checks to confirm all changes.

On the VAO server, run readiness checks for all orchestration plans to make sure there are no errors related to connections to Veeam Backup & Replication servers.

More Information

DOWNLOAD UPDATE



MD5 for kb2992.zip: b3fa2e825cade1804fe5938531af85fd
SHA-1 for kb2992.zip: for f2969912c929b373c5babb55a8f6f3ce38410b8b
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please, try again later.