#1 Global Leader in Data Resilience

How to Reset the Veeam Agent for Microsoft Windows Configuration Database

KB ID: 2335
Product: Veeam Agent for Microsoft Windows | 6.0 | 6.1 | 6.2
Published: 2017-09-15
Last Modified: 2024-03-01
mailbox
Get weekly article updates
By subscribing, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.

Cheers for trusting us with the spot in your mailbox!

Now you’re less likely to miss what’s been brewing in our knowledge base with this weekly digest

error icon

Oops! Something went wrong.

Please, try again later.

Resetting the configuration database will reset all Veeam Agent for Microsoft Windows settings, removing existing job settings and related job history. Restore points created before the reset will not be removed and will remain recoverable; however, as their job will have been removed, they will not be tracked for retention.

Purpose

This article documents how to reset the Veeam Agent for Microsoft Windows local configuration database.

Solution

Set the RecreateSQLiteDatabase value in the registry to 1 to force the recreation of the SQLite Database during the next start of the Veeam Agent for Microsoft Windows service.

Key Location: HKLM\SOFTWARE\Veeam\Veeam Endpoint Backup
Value Name: RecreateSQLiteDatabase
Value Type: DWORD (32-Bit) Value
Value Data: 1

Set-ItemProperty -Path 'HKLM:\SOFTWARE\Veeam\Veeam Endpoint Backup' -Name 'RecreateSQLiteDatabase' -Value "1" -Force
Restart the Veeam Agent for Microsoft Windows service.
During the start-up of the Veeam Agent for Microsoft Windows service, a new configuration database will be created, and the registry value data will be reset to 0, ensuring that this only occurs once.
Restart-Service VeeamEndpointBackupSvc
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please, try again later.