If you connect to vCenter Server 5.1 or 5.5, Veeam MP/SPI 5.7 will not collect some data, including hardware sensor metrics and vCenter-specific events and properties that were introduced by VMware since VMware vSphere 4.0. vCenter events and properties that were introduced before VMware vSphere 4.0 will be collected without errors.

Cause

Although as per the system requirements the Veeam MP/SPI 5.7 does not support the VMware vSphere 5.1/5.5 platforms, it is possible to configure a connection to vCenter Server 5.1/5.5 in the Enterprise Manager Web UI.

Solution

To resolve the issue, apply the Veeam MP/SPI 5.7 patch 5.7.0.1056 available on the Veeam MP and Veeam SPI downloads web pages, following this link.

More Information

With this patch applied, nworks 5.7 MP/SPI are compatible with all vSphere 5.x versions. All functionality introduced for support of vSphere 5.0 will be available. Note that no additional events or metrics specific to vSphere 5.1/5.5 will be collected.

Note, that once the patch is applied, you will see a warning in nworks UI, because the collector version will be later than that of the Enterprise Manager. The warning is expected and does not indicate any issue; it can be safely ignored.

To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please, try again later.